Specifications |
fifty-five point three two | fifty-five point three three | fifty-five point three four | |
Contact specifications | ||||
Contact configuration | 2 CO (DPDT) | 3 CO (3PDT) | 4 CO (4PDT) | |
Rated current / maximum peak current a | 10/20 | 10/20 | 7/15 | |
Rated voltage / maximum switching voltage V AC | 250/400 | 250/400 | 250/400 | |
Rated load AC1 VA | two thousand and five hundred | two thousand and five hundred | one thousand seven hundred and fifty | |
Rated load ac15 (230 V AC) VA | five hundred | five hundred | three hundred and fifty | |
Single phase motor rating (230 V AC) kw | zero point three seven | zero point three seven | zero point one two five | |
Breaking capacity dc1:30/110/220 V A | 10/0.25/0.12 | 10/0.25/0.12 | 7/0.25/0.12 | |
Minimum switching load MW (v/ma) | 300 (5/5) | 300 (5/5) | 300 (5/5) | |
Standard contact material | AgNi | AgNi | AgNi | |
Coil specification | ||||
Nominal voltage (UN) | V AC(50/60 Hz) | 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 | ||
V DC | 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 | |||
Rated power ac/dc VA (50 Hz) /w | 1.5/1 | 1.5/1 | 1.5/1 | |
Operating range | AC | (0.8…1.1)UN | (0.8…1.1)UN | (0.8…1.1)UN |
DC | (0.8…1.1)UN | (0.8…1.1)UN | (0.8…1.1)UN | |
Holding voltage ac/dc | 0.8 UN / 0.5 UN | 0.8 UN / 0.5 UN | 0.8 UN / 0.5 UN | |
Required voltage ac/dc | 0.2 UN / 0.1 UN | 0.2 UN / 0.1 UN | 0.2 UN / 0.1 UN |